DISTRIBUTOR PUSAT TOKO PERALATAN PERLENGKAPAN FIRE ALARM MANUAL CALL POINT PULL STASION 2 WIRE SENSOR HARGA MURAH JAKARTA
Spesification:2-wire Conventional Manual Call Point;
Item No.: HS-SB116
Alarm Current: 10-30 mA @ 24 VDC
Operating voltage: DC 24 volt
Resettable: By using the key to open the case
Material: ABS
Dimensions: 140*105*45mm
Weight: 220g
General Description
Conventional Manual call point designed for conventional fire alarm system for reporting fire or emergency condition by its PUSH IN/PULL DOWN handle latches. One 470 ohm resistor is used on the PCB board between Zone+ and Zone- when the switch inside is closed. So the conventional manual call point is only used with conventional fire alarm control panel, it is forbidden to be used to other system.
Operation
The manual call points provide a textured finger-hold area that includes braille text. In addition to PUSH IN and PULL DOWN text, there are arrows indicating how to operate the station, provided for non-English-speaking people.
Pushing in and then pulling down on the handle activates the normally-open alarm switch. Once latched in the down position, the word "ACTIVATED" appears at the top in bright yellow, with a portion of the handle protruding at the bottom as a visible flag.
Resetting the station is simple: insert the key, twist one quarter-turn, then open the station's front cover, causing the spring-loaded operation handle to return to its original position. The alarm switch can then be reset to its normal (non-alarm) position manually (by hand) or by closing the station's front cover, which automatically resets the switch.
Loop Design and Wiring
The fire alarm control panel Zone wire can be connected to terminal loop (+), loop (-) unpolarized wire.
If the manual call point is in the end of the zone wire, a 5.6K resistance should be connected to terminal loop (+), loop (-).
Installation
NOTE: All wiring must conform to applicable local codes, ordinances, and regulations.
Mounting Indoor Wall
1. Attach mounting base to wall at 1.5 meter's high
1. Connect field wiring to terminals
3. To attach product to mounting base
4. Secure product by tightening the one mounting screws in the front of the product housing.
MOQ : 6 PCS
----------------------------------------------------------------------------------------------------------
* Spesifikasi dan Harga dapat berubah tanpa pemberitahuan sebelumnya
-----------------------------------------------------------------------------------------------------------
pembelian via offline
Info harga & detail spesifikasi hubungi:
Handphone:
0853 1233 3289 ( WA )
0812 9723 9269 ( WA )
0878 8576 4888
0878 7853 3449
Www•JakartaSafetyOnline•Com
Www•PemadamApiOnline•Com
Www•CctvGrosirMurah•Com
Www•PusatBrankas•Com
UD. Jakarta Safety & Security
Green Sedayu Bizpark, DM 10/56.
Daan Mogot Km 18, 11840, Kalideres, Jakarta